Is it safe?
The shockwaves used in therapy have controlled energy and are targeted, affecting only the area to be treated. The treatment is usually performed by a trained professional who adjusts the energy and intensity to the specific condition.
What side effects can occur?
Shockwave therapy is generally a well-tolerated procedure; however, as with any treatment, temporary side effects can rarely occur.
Possible side effects:
- temporary pain or tenderness in the treated area
- mild local inflammation
- bruising (blue-green discoloration)
- tingling, numbness-like sensation (paresthesia)
- redness (erythema)
- very rarely, soft tissue, tendon, or fascia injury
Important to know:
These symptoms are typically mild and temporary, and in most cases, they resolve on their own within a few days, at the latest within a week, even before the next treatment session.
When should shockwave therapy not be used?
In certain cases, treatment is not recommended or requires increased caution. For safety, a professional performs an assessment before every treatment.
Absolute contraindications: (Treatment cannot be performed in these cases.)
- Active infection in the treated area (e.g., osteomyelitis)
- Malignant tumor in the treatment area (especially with focused shockwaves)
- Pregnancy
Relative contraindications: (Increased caution is required, especially with high-energy treatments.)
- Brain or nerve tissue near the treatment area
- Lungs or pleura in the treatment focus
- Severe blood clotting disorder
- Growth plate (epiphysis) in the treatment area
Important professional considerations before treatment:
- It is essential to report any of the following before starting treatment:
- Implanted pacemaker or other implant
- Regular use of non-steroidal anti-inflammatory drugs (NSAIDs)
Anticoagulant therapy
- Recent corticosteroid injection to the treated area
- If you are unsure whether shockwave therapy is suitable for you, always consult a professional before use.
What are the signs/events that definitely warrant turning off the product?
- Fluid or foreign objects entering the device
- Overheating or leakage
- Unusual noise
- Unpleasant smell or smoke
- Damaged accessory/head
In what environment is it not recommended to use?
It is not recommended to operate the device in hot, humid, dusty, or oily environments.
Does it have wear and tear parts?
Yes. The striker is a wear and tear part and must be replaced after a specified number of impacts. It withstands approximately 25 million impacts.
What should I do if I experience a problem during use?
If you experience any discomfort, pain, unusual sensation, or technical problem:
- immediately turn off the device,
- unplug it from the mains,
- and contact a specialist or warranty service.
What should I pay particular attention to during use?
- Do not treat fresh injuries or acute inflammation.
- Do not cover the vents to avoid overheating.
- Check the power cable and accessories before each use.
Are there any devices or methods with which it is not recommended to combine?
In general, it is not recommended to perform treatment simultaneously with other intensive physical therapies (e.g., intensive massage, other strong mechanical therapies), especially in cases of inflammatory conditions.
Are there any age requirements?
1. Children and adolescents:
- Generally only to be used under medical supervision, with special indications.
- Bones and tissues are still growing, so the treatment energy should be set at a lower level.
- In rare cases, it is used for orthopedic or sports injury treatment, but always based on a specialist's decision.
2. Adults (18–65 years):
- The most common target group: chronic muscle and joint pain, sports injuries, as a complement to physiotherapy.
- Safe and effective if contraindications are not present (e.g., cancerous lesions, pacemaker, acute inflammation).
3. Older adults (65+):
- Due to reduced tissue elasticity, it may be necessary to start with lower energy or shorter treatment times.
- Joint wear, osteoporosis, or medication are common, so medical consultation is always required.
- Generally, treatment is comfortable and well-tolerated, but gradual progression is key.
What safety conditions can the product have?
1. Always read the entire user manual and recommended treatment chart before use.
2. Always stand or sit on a stable surface during treatment – the device may cause vibration and movement during operation.
3. Do not treat damaged, inflamed, or infected skin areas with the device.
4. Do not attempt to treat areas causing psychic sensations or areas in the immediate vicinity of metal implants.
5. Do NOT use the device on persons with pacemakers or other implanted medical electronic devices without medical approval.
6. Do not use without prior medical consultation in cases of cardiac arrhythmia, cancerous disease, or severe vascular changes.
7. During pregnancy, perform shockwave treatment only on medical advice.
8. Avoid using the device directly over the eyes, spinal cord, heart, liver, and kidneys.
9. Always start treatment with low energy and frequency levels, and only slowly increase the settings.
10. Do not use maximum intensity during the first sessions – this can cause excessive pain or discomfort.
11. Never leave the treatment head on a single small area for longer than recommended in the manual (usually 3–5 minutes).
12. For children or young users, use only under adult supervision and with full instructions.
13. Do not use the device on wet, sweaty skin or near water.
14. Do not attempt to disassemble, modify, or repair the device yourself – this is dangerous and invalidates the warranty.
15. Keep the treatment heads clean and disinfected for hygiene – weekly or depending on frequency of use.
16. Do not treat fresh injuries, acute inflammation, or bruises with the device – wait for healing or consult a doctor.
17. Do not let the device's cable or treatment head obstruct movement – always position it stably.
18. Before first use, check the integrity of the device, head connectors, and cables.
19. During use, if you experience severe, sharp pain, dizziness, or tingling, immediately stop the device.
20. This device is for regenerative and supportive purposes – it does not replace professional medical diagnosis or treatment.